Dust Collector Fan
Lots of blower fans that work in dust collector and air purification systems need to deal with dirty air, even high temperature and corrosive gas. We design the Dust collection fan, Flue gas desulfurization fan, Flus gas dentitrification fan, Abrasion fan and corrosion resistant fan for dust collecting system, gas desulfurization system, denitration system, in addition to provide adequate performance, the impeller, shaft, and casing of fan will be enhanced wear and corrosion resistance, extend the service life more than 3 times, helping the customer to save the cost of use and maintenance.
Description
Features
Specification
Lots of blower fans that work in dust collector and air purification systems need to deal with dirty air, even high temperature and corrosive gas. We design the Dust collection fan, Flue gas desulfurization fan, Flus gas dentitrification fan, Abrasion fan and corrosion resistant fan for dust collecting system, gas desulfurization system, denitration system, in addition to provide adequate performance, the impeller, shaft, and casing of fan will be enhanced wear and corrosion resistance, extend the service life more than 3 times, helping the customer to save the cost of use and maintenance.
parameters
10000-1000000Nm³/h, pressure: 1000-8000pa, working temperature: 20-250℃.
peculiarity
1. The aerodynamic model is used for fluid simulation, which greatly improves the design accuracy of the fan, and the efficiency of the whole machine is high.
2. The wear-resistant part of the impeller adopts surfacing welding and wear-resistant treatment to meet the airtightness requirements of the desulfurization system.
3. The key operating components are selected from well-known brands at home and abroad, which effectively improves the operation reliability of the fan products.
-
01
High temperature measures: high temperature resistant alloys, reasonable cooling measures, and scientific anti-high temperature deformation structure
-
02
Wear-resistant measures: high-hardness composite materials to ensure the use of the impeller and prolong its life
-
03
Anti-corrosion measures: a variety of anti-corrosion measures to adapt to different corrosion conditions
-
04
High-efficiency products: high-efficiency models optimized by simulation analysis, strict processing process
-
-
-
serice |
model |
Air Capacity(m³/h) |
Total Pressure(Pa) |
High Efficiency(10%) |
Rotation Speed(r/min) |
【4-10】 |
No8D~29.5D |
15900~812000 |
1190~8050 |
87.1 |
730~1450 |
No20F~31.5F |
121000~1550000 |
2140~9100 |
85.5 |
730~960 |
【5-10】 |
No8D~29.5D |
13740~647000 |
1540~10500 |
87 |
730~1450 |
No20F~35.5F |
108000~1460000 |
2450~12500 |
83.1 |
730~960 |
【5-12】 |
No8D~30D |
10000~533445 |
1000~15000 |
85 |
730~1450 |
No20F~35F |
100000~1024655 |
1000~15000 |
83 |
730~960 |
【6-18】 |
No8D~30D |
8730~621000 |
780~10790 |
86 |
730~1450 |
No20F~35.5F |
103720~1480000 |
2805~13600 |
83.2 |
730~960 |
【7-05】 |
No8D~28D |
6550~401000 |
1120~12500 |
86.5 |
730~1450 |
No20F~33.5F |
77820~1050000 |
4030~13400 |
83 |
730~960 |