You are here: Home > Products > Environmental Protection Industry

Desulfurization booster fan

In order to reduce air pollution, industrial furnaces must strictly control the emissions of SO2, etc. Therefore, desulfurization devices are required. Due to the high resistance of desulfurization devices, in addition to using induced draft fans to overcome the resistance of the smoke and air system, it is also necessary to install desulfurization boosters. Compressor fan to overcome the resistance of the desulfurization device.SIMA blower has long served the power generation industry. Whether it is used for industrial boiler system blower, induced draft fan, smoke exhaust fan, primary fan, secondary fan, or dust removal fan for gas purification system , desulfurization fan, denitrification fan, SIMO BLOWER  has provided a large number of fan systems with reliable performance and stable operation for customers in the power generation industry.
 
Share With :
Description
Features
Specification
In order to reduce air pollution, industrial furnaces must strictly control the emissions of SO2, etc. Therefore, desulfurization devices are required. Due to the high resistance of desulfurization devices, in addition to using induced draft fans to overcome the resistance of the smoke and air system, it is also necessary to install desulfurization boosters. Compressor fan to overcome the resistance of the desulfurization device.SIMA blower has long served the power generation industry. Whether it is used for industrial boiler system blower, induced draft fan, smoke exhaust fan, primary fan, secondary fan, or dust removal fan for gas purification system , desulfurization fan, denitrification fan, SIMO BLOWER  has provided a large number of fan systems with reliable performance and stable operation for customers in the power generation industry.
 
overview
(1) Application: It is mainly used for the dilution of flue gas denitrification reducing agent ammonia in 100mw-600mw power plants, so that the ammonia gas from the ammonia buffer tank is diluted and mixed by the ammonia/air mixer to dilute the concentration of ammonia gas .

(2)parameter scale:5000-1050000Nm³/h, pressure: 5000-20000pa, working temperature: 20-400℃.
 
(3) Model: According to the parameters such as air volume and pressure required by the design, the main model of the selected fan is a high-pressure centrifugal fan.
 
(4) Features: It has the advantages of good aerodynamics, high efficiency, stable operation, and simple maintenance
peculiarity
1. The aerodynamic model is used for fluid simulation, which greatly improves the design accuracy of the fan, and the efficiency of the whole machine is high. 
 
2. Adopt high temperature resistant alloy, reasonable cooling measures, and scientific anti-high temperature deformation structure. 
 
3. The key operating components are selected from well-known brands at home and abroad, which effectively improves the operation reliability of the fan products.

01

 High temperature measures: high temperature resistant alloys, reasonable cooling measures, and scientific anti-high temperature deformation structure

02

Wear-resistant measures: high-hardness composite materials to ensure the use of the impeller and prolong its life

03

Anti-corrosion measures: a variety of anti-corrosion measures to adapt to different corrosion conditions

04

High-efficiency products: high-efficiency models optimized by simulation analysis, strict processing process

 

serice model Air Capacity(m³/h) Total Pressure(Pa) High Efficiency(10%) Rotation Speed(r/min)
【4-10】 No8D~29.5D 15900~812000 1190~8050 87.1 730~1450
No20F~31.5F 121000~1550000 2140~9100 85.5 730~960
【5-10】 No8D~29.5D 13740~647000 1540~10500 87 730~1450
No20F~35.5F 108000~1460000 2450~12500 83.1 730~960
【5-12】 No8D~30D 10000~533445 1000~15000 85 730~1450
No20F~35F 100000~1024655 1000~15000 83 730~960
【6-18】 No8D~30D 8730~621000 780~10790 86 730~1450
No20F~35.5F 103720~1480000 2805~13600 83.2 730~960
【7-05】 No8D~28D 6550~401000 1120~12500 86.5 730~1450
No20F~33.5F 77820~1050000 4030~13400 83 730~960